Description
The SurgeX SX-1120-RT rack mount surge protector offer comprehensive power protection and conditioning to safeguard AV equipment from harmful electrical transients that can cause malfunction and downtime. They allow technicians to turn equipment on or off remotely for quick reboots that can reduce service calls.
Features:
- Remote turn-on
- Thermal circuit breaker overload protection
- Self-test circuit with visual indicator
- Magnetic shielding steel enclosure
- Non-sacrificial components
- 9′ grounded 3-wire cord
| Subject to the use of all the optional accessories | |
| Load Rating | 20 amps at 120 volts |
| Power Requirement (no load) | 15 watts |
| Surge Let-Through Voltage (6000-volt surge) | 0 volts |
| UL 1449 Adjunct Classification Test Results | 1000 surges, 6000 volts, 3000 amps, B3 pulse. |
| Measured suppressed voltage | 170 volts, no failures |
| Federal Guidelines | Grade A, Class 1, Mode 1 (CID A-A-55818) |
| EMI/RFI Filter, Normal Mode (50-ohm load) | 40 dB at 100 kHz; 50 dB at 300 kHz; 50 dB at 3 MHz; 50 dB at 30 MHz |
| EMI/RFI Filter, Common Mode (50-ohm load) | 18 dB at 300 kHz; 30 dB at 1 MHz; 50 dB at 5 MHz; 50 dB at 20 MHz |
| Maximum Applied Surge Voltage | 6000 volts |
| Endurance (C62.41-1991 Category B3 pulses) | 1 kV > 500,000; 3 kV > 10,000; 6 kV > 1000 |
| Undervoltage Shutdown | 90 volts (resume at 100 v) |
| Overvoltage Shutdown | 145 volts (resume at 135 v) |
| Maximum Load Inrush Current During Power-up | 1000 Joules |
| Remote Turn-on Applied Voltage Range | 5 to 30 volts DC |
| Contact Closure | 1.5 mA |
| 5 V DC Applied Voltage | 0.1 mA |
| 12 V DC Applied Voltage | 1.5 mA |
| 24 V DC Applied Voltage | 5.0 mA |
| Auxiliary Relay Contact Rating | 30 Volts at 1 Amp |
| LED Output | 12 volts DC, maximum 20 mA (resistor required) |
| Dimensions | 1.75″ H x 19″ W x 10.5″ D (4.5 x 48.3 x 26.7 cm) |
| Weight | 11 lbs (5 kg) |
| Temperature Range | 5° to 35° C |
| Humidity Range | 5% to 95% R.H., non-condensing |
| Agency Listings | ETL and cETL certified to (UL 1449; CSA C22.2 No.8-M1986, R2000) |